Integral Magnetic flowmeter

時間:2019-01-14人氣:

Food grade electromagnetic flow meter china manufacture

 

Electromagnetic flow meters, or magmeters, are comprised of a transmitter and sensor that together to measure flow. The magnetic flow meter’s sensor is placed inline and measures an induced voltage generated by the fluid as it flows through a pipe. The transmitter takes the voltage generated by the sensor, converts the voltage into a flow measurement and transmits that flow measurement to a control system.

 China Food Grade Electromagnetic flow meter charactor

 

  • Easy Setup
  • Minimal Straight Pipe
  • Mounted or Remote Rate and Total
  • IP65,IP67 ,IP68 Rated (optional)
  • 100:1 Turndown
  • Virtually No Pressure Loss
  • No Moving Parts
  • RS485 Standard,HART standard is available.
  • Suitable for Pipes Up to DN3000
  • High Accuracy to 0.2%R .
  • 4 to 20 mA and Frequency Outputs Standard
  • 3-Point Calibration Included
132

Electromagnetic flowmeter parameters

 

Model

DN6~DN3000mm

Nominal Pressure

0.6~1.6MPa(2.5Mpa/4.0Mpa/6.4Mpa...42Mpa)

Accuracy

±0.5%,±0.3%or±0.2% are available

Liner material

Teflon,PFA,F46,Neoprene,Polyurethane

Electrode Type

General type 

Electrode material

Stainless steel SUS316,Hastelloy B, Hastelloy C,Titanium,Tantalum  Platinum-iridium,
Stainless steel covered with tungsten carbide

Mediem temperature

Integral type

-20°C~+60°C

Remote type

Neoprene & Polyurethane Liner

-10°C~+80°C

 PTFE Liner /PFA Liner /F46 Liner

-10°C~+160°C

Ambient Temperature

-25°C ~+ 60°C

Ambient Humidity

 5~100%RH(relative humidity)

Medium Electrical 
conductivity

≥5μ s/cm

Measuring Range

1500:1,flow rate<15m/s

Structure type 

Integral type,remote type,submersible type,ex-proof type

Protection Class

IP65,IP68(optional)

Ex-proof Mark

ExmdⅡT6

Product Standard

JB/T 9248-1999 Electormagnetic Flowmeter

 


Calibration is the most important procedure of manufacturing the high accuracy flowmeter,As the principle is the same,the material and the structure design of the flowmeter is not much different.High accuracy flowmeters depends on the high accuracy calibration equipment.

 Fantai Electromagnetic flowmeter advantages in details

 

  • We use the reference flowmeter method to confirm the sensor condition,then after assemble,we will use the gravimetric systems to confirm the sensor and the transmitter condition.The calibration device included the high accuracy Sartorius scale.Our high accuracy Sartorius scale can reach the 0.016%.so it is no problem to gurantee the 0.2% accuracy. 
  • We use the AB clue to fix the bolts and nuts in case it may loose because of the vibration and long distance transportation
  • The welding of the housing and the flange are operated by our senior welding engineers who have at least 5 years experience.The inner flange is welded completely to make sure no humidity enter into the flowmeter house.
  • The thickness of the linner is more than 3mm.
  • The exciting coil of wires are copper wire.
  • We use the label to remind customer where to connect the power and voltage in case the unmatched voltage damage the flowmeter.
  • The big screen LCD display the forward gross volume,flow volume and unit clearly.
  • Flowmeter use the matched grounding rings to keep high accuracy measurement stable                                                  

Related products

          電   話:0371-23212206           

郵   箱:[email protected]

彩票极速赛车计划网页 快乐8走势图表 安徽十一选五开奖结果一定牛 赚钱软件一元提现 双色球100期开奖走势图 湖南投资股票行情 手机打字赚钱官网 内蒙体彩11先5开奖号码 安徽快三人工计划 快乐十分开奖结果云南体彩 河北快3彩票官网